Weifang Yuxing Power Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. sui andrea
  • Company Name : Weifang Yuxing Power Co., Ltd.
  • Tel : 86-536-8790229
  • Fax : 86-536-8790229
  • Address : Shandong,weifang,hexi village industial park beihai south road weifang high-tech zone
  • Country/Region : China
  • Zip : 261206

75GF-120GF diesel generator(93KVA-150KVA diesel genset)

75GF-120GF diesel generator(93KVA-150KVA diesel genset)
Product Detailed
Related Categories:Diesel Generators

Detailed Product Description


  

Model

75GF-120GF

Rated PowerKW

75KW-120KW

Power factor

0.8

Rated voltageV

400/230

Rated electricityA

135.3-216.5

Rated frequencyHZ

50

Output mode

Three-phase,four-write

Model

R6105D1

R6105ZD1

R6105ZD4

R6105ZLD

R6105AZLD

Type

Four-stroke, water-cooled, in-line,direct injecting combustion chamber

Cylinder NO.-Bore/stroke(mm)

6-105*125

Displacement(L)

6.49

 Rated power/speed
(kW/r/min)

58/1500

84/1500

75/1500

100/1500

121/1500

Starting method

Electric

Cooling method

Forced water cooling

Lubrication

Coppound type with pressure and splash 

Crankshaft Ratating Direction

Ounter clockwise( Facing to the power out put end)

Fuel consumption(g/kW.h)

231

224

218

218

Air intake mode

Naturally aspirated

Turbocharged

Turbocharged intercooled

75GF-120GF diesel generator specifications:

1) Output range:  Output range:70KW-120KW/ 93KVA-150KVA

2) Engine details: Ricardo series

3) Alternator details: Stamford series, Marathon series, Lerysomer series, and so on.

4) Water-cooled

5) 8hrs operation base tank

6) Key start / auto start

7) Sound-proof / weather-proof canopy is optional

8) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires alternating current output

9) Frequency: <3%

10) Frequency at stable state: <0.5%

11) Frequency deviation at instantaneous state: ≤+10%

12) Frequency return time: ≤3s

13) Voltage deviation at stable state: ≤±1%

14) Voltage deviation at instantaneous state: ≤+20%

15) Voltage return time: ≤4s

16) Voltage modulation: ≤0.3%

17) Standard configuration of gensets: a) Engine: R series diesel engine

b) Engine type: water-cooled, in line four-stoke, direct injection c) Alternator: Marathon brushless alternator

18) Control system: a) Automatic alarm system: the unit has the acoustic-optics

alarm system and arrestor for any situation as the start defeat, the water is

over temperature, the oil pulls down, over speed, over load and over current b)

Operation display: i) Unit voltage, tri-phase load current and frequency display

ii) Water temperature, oil pressure display iii) Fuel level, fuel temperature

display iv) Audible and visual alarm lamps and buzzers

19) Starting system: DC alternator is used to start engine

20) Short circuit protection: MCCB air switch

21) Cooling system: combined cooling water tank fitted to meet the requirement

of radiation at ambient temperature 40°C

22) Filter system: oil, fuel and air filter

23) Accessories: exhaust elbow, bellow, muffler

24) Supply standard collocation:

a) Diesel engine with all accessories, 3 filter, electric systems

b) Alternator

c) Steel structure

d) Fan and water tank cooling system

e) Flange connector

f) 12 / 24V starting motor and charge engine

g) Air cleaner, fuel cleaner, oil cleaner

h) On-board control panel

i) MCCB air conservation switch

j) 12 / 24V starting accumulator and Battery line

k) Set shock absorber

l) High-efficient silencerInner

25)packing: packing in Wooden cases



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.